Brief Description of the Line

- The speed on the line is between 350 and 400 pieces /minute
- Vial format of 3 ml is coming with the machine.
- Other formats can be purchased from OEM
- Leak testing by vacuum ( vacuum is created through vacuum pump included in the machine)
- The line was installed in 2011, all FAT tests have been passed.
- The machine has never been used in production
- These line are identical to modern /current lines with the only difference lying with a software upgrade.
Brief Description of the machine that form the Line
Brand: Neri
Model: PS 160-1500 T1
Yom: 2015
Weight: 300 kg
Voltage: 3 X 400V + PE
Frequency: 50 Hz
Brand: Wilco
YOM: 2010
Weight: 6000 kg
Number of test sites: 48, Station
Closure: mechanical cam,
Test method: V - differential vacuum,
Detectable leakage:> 10 microns
Noise:< 75 dB(A) ,
Brand: Neri
Model: TM2
Yom: 2009
Power: 1,5 KW
Weight: 350 kg
Brand: Neri
Model: PS 160-1500 T1
Yom: 2015
Weight: 300 kg
Lot Number : 276574,276575

Number of test sites: 48, Station
Closure: mechanical cam,
Test method: V - differential vacuum,
Product to test:3 & 9 ml bottles
Detectable leakage:> 10 microns
Noise:< 75 dB(A) ,
Brand: Neri
Model: TM2
Yom: 2009
Power: 1,5 KW
Weight: 350 kg
Machine specification:
WOM: approx. 3000 kg (depending on machine version)
Electric Supply: 380 V, 50 cycles from mains
Connected Load: 13 kW
Average Power Consumption: 7 kW
Machine performance:
Output: max. 300 blisters/min.
Cycling speed:
min. 15 cycles/min.
max. 60 cycles/min
Brand : Steriline
Model: VQ 1 F44
YOM: 1995
Liquid Process: 35.000 Vial
Vial Size: 3 or 4 ml
Washing Unit: 380V
Frequency: 50 Hz
Revent: 2011
Brand : TL System
Model: 8920
YOM: 1995
S/N: 8920
Liquid Process: 35.000 Vial
Lyo Process: 25.000 Vial
Vial Size: 3 or 4 ml
Capacity: 35.000 vial/hour
Revent: 2011
Brand : Zalkin
Model: CAPM ST 20
YOM: 1995
LOT NR: B005
CAPACITY:
-
3 ml liquid 35000 pcs / hour
-
3 ml Lyo 25000 pcs / hour
FORMAT: 3 ml, capsules 13mm
VOLTAGE: 220/380 V three-phases.
Frequency: 50 Hz
FILLING LINE
• The maximum speed of the line is 12000 vials/h
• The vials size are :
3-4 ml ( same format parts ) and 7 ml.
• Software currently installed S7 - 1500 Siemens
• After overhauled machine never used in operation (only testing)
• Multi size vials
• For filling heads
• By an additional fine adjustment device
Sterilization Oven
When the vials have been transferred to the front of the static oven, They will open the front of the static oven, and the trays go inside.
Afterwards, the trays will go into the back of the oven.
-Production speed is 12000 vials/hour
-Formats coming with the line is 3 ml and maybe 7 ml.
Washing Unit
The vials are put into this washing unit, this washing unit works with the vials are been put upside down in the trays inside this washing unit.
The Vials will be rinsing, cleaning and drying.
When the vials have been rinse, clean and dry, they will put the vials on the trays and pick up by trolleys, then transfer the vials to the front of the static oven.